Installation Proline Prosonic Flow 91W
18 Endress+Hauser
A0011373
Fig. 16: Coating the contact surfaces of the sensor with coupling fluid
8. Insert the sensor into the sensor holder.
9. Fit the sensor cover on the sensor holder and turn until:
The sensor cover engages with a click
The arrows (Å /
Æ
"close") are pointing towards one another.
10. Screw the connecting cable into the individual sensor.
A0001115
Fig. 17: Mounting the sensor and connecting the connecting cable
This completes the mounting process. The sensors can now be connected to the transmitter via
the connecting cables ä 9.