EasyManua.ls Logo

Endress+Hauser Proline Prowirl 73 - Mechanical Construction

Endress+Hauser Proline Prowirl 73
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Prowirl 73 F, W
14 Endress+Hauser
Pressure-temperature curve according to ANSI B16.5 and JIS, stainless steel
ANSI B 16.5:
Class 150...300 Prowirl 73 W und 73 F
Class 600 Prowirl 73 F (in preparation)
JIS B2238
10...20 K Prowirl 73 W und 73 F
40 K Prowirl 73 F (in preparation)
F06-7xxxxxxx-05-xx-xx-xx-001
Pressure loss The pressure loss can be determined with the aid of the Applicator, a software for selection and sizing of
flowmeters. The software is available both via Internet (www.applicator.com) and on a CD-ROM for local
PC installation.
Mechanical construction
Design, dimensions Dimensions of transmitter, remote version
F06-72xxxxxx-06-03-00-xx-000
* The following dimensions differ depending on the version:
The dimension 232 mm changes to 226 mm in the blind version (without local operation).
The dimension 150 mm changes to 163 mm in the Ex d version.
The dimension 345 mm changes to 368 mm in the Ex d version.
-200 -100
0
20
40
60
80
100
120
0 100 200 300 400
°C
bar
Class 150...600
Cl. 150
Cl. 300
Cl. 600
-200 -100
0
5
10
15
20
25
30
35
40
45
0 100 200 300 400
°C
bar
10...40 K
40 K
20 K
10 K
123
133
195
150 (163)*
345 (368)*
100
100
25
Ø 8.6 (M8)
232 (226)*
Esc
E
-
+

Other manuals for Endress+Hauser Proline Prowirl 73

Related product manuals