Wiring Prosonic M - FOUNDATION Fieldbus
28 Endress+Hauser
4.1.2 Wiring in the housing T12
4.1.3 Terminal assignment
L00-FMxxxxxx-04-00-00-en-013
1. Unscrew the cover (1) of the separate
connection room.
2. Insert cable (2) through gland (3).
"
Caution!
If possible, insert the cable from above and
let a draining loop in order to avoid
intrusion of humidity.
3. Connect cable screen to the grounding
terminal (4) within the connection room.
4. Make connection according to the terminal
assignment (see below).
5. Tighten cable gland (3).
6. Screw on housing cover (1).
7. Switch on power supply.
L00-FMU4xxxx-04-00-00-yy-009
3
2
12
3
4
4
1
3
4
1
2
+–
plant
ground

Table of Contents