Prosonic M - FOUNDATION Fieldbus Accessories
Endress+Hauser 71
9.4 Cantilever
L00-FMU4xxxx-06-00-00-yy-005
Dimensions in mm
The 50 mm (2.17 in) or 62 mm (2.44 in) orifices serve for the mounting of the FMU40 or FMU41
sensor, respecitvely.
The 22 mm (0.87 in) orifice may be used for an additional sensor.
For the mounting of the cantilever can be used:
mounting frame ä 72
wall bracket ä 72
A
DM8
35
50
20
20
105
50/
62
22
C
C
6.5
15
100
25
351007575 B
A B C D for Sensor Material Order Code
585 (23) 250 (9.84) 2 (0.08) 200 (7.87) 1½" 316Ti (1.4571) 52014132
galv. steel 52014131
2" 316Ti (1.4571) 52014136
galv. steel 52014135
1085 (42.7) 750 (29.5) 3 (0.12) 300 (11.8) 1½" 316Ti (1.4571) 52014134
galv. steel 52014133
2" 316Ti (1.4571) 52014138
galv. steel 52014137