EasyManua.ls Logo

Endress+Hauser prowirl 70 - HART and INTENSOR Communication; HART Connection for EEx ib; HART Connection for EEx d

Endress+Hauser prowirl 70
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
Prowirl 70 Transmitter
Housing material Cast aluminum, painted
Protection type Compact version: IP 65 (DN 60529)
Remote version: IP 67
Ambient temperature -40...+80 °C (depending on process temperature)
(see page 21)
Vibration immunity 1g to 500 Hz (in all directions)
Electromagnetic
compatibility (EMC)
IEC 801 part 3: E = 10 V/m (80 MHz...1GHz);
IEC 801 part 6: Uo = 10 V (9 kHz...80 MHz)
Power supply 12...30 V DC (without HART, INTENSOR)
18.5...30 V DC (with HART, INTENSOR)
Cable glands PG 13.5
Threads for cable glands M20 x 1.5 or
1
2
" NPT or G
1
2
"
Power consumption <1 W
Galvanic isolation Between process and outputs
Current output 4...20 mA analogue current output,
full-scale value and time constant may be set
PFM current pulse programmable, pulse width
0.18 ms
Open collector output I
max
10 mA, U
max
= 30 V, R
i
= 900
(HART: only to R
L
10 k)
Pulse output; pulse scaling selectable,
f
max
= 100 Hz, 50/50 duty cycle
Alarm contact
Limit switch; on/off points selectable
Display LC display; 4 character with decimal point.
Bar graph for analogue display of flowrate in %
Communication HART protocol via current output,
INTENSOR protocol via current output
Data storage DAT memory module stores all programmed data
(without battery)
Hazardous area approvals
Intrinsically safe CENELEC EEx ib IIC T6
FM IS Cl. I, II, III Div. 1 Gr. A-G
CSA IS Cl. I; Div. 1/Div. 2 Gr. A-D,
Cl. II; Div. 1/Div. 2 Gr. E-F, Cl. III; Div. 1/Div. 2
Explosion proof CENELEC EEx d IIC T6
FM XP Cl. I Div. 1 Gr. A-D
CSA XP Cl. I Gr. B-D, Cl. II Gr. E-G, Cl. III
Note: Remote version has no Ex d
Accuracy limits (measuring system)
Liquids <0.75% o.r. at Re
D
>20000
<0.75% o.f.s. at Re
D
4000...20000
Gas/steam <1% o.r. at Re
D
>20000
<1% o.f.s. at Re
D
4000...20000
Current output Temperature coefficient <0.03% o.f.s./°C
Maximum flow velocity Liquids: v
max
= 9 m/s
Gas/steam: v
max
= 75 m/s;
DN 15: v
max
= 46 m/s
Reproducibility ±0.2% o.r.
23

Other manuals for Endress+Hauser prowirl 70