Measuring Ranges
Meter Bodies
The following tables are given as
guideline for measuring ranges, vortex
frequency ranges and K-factors for a
typical gas (air at 0 °C and 1.013 bar)
and a typical liquid (water, at 20 °C).
Your E+H sales organisation will be
pleased to help you select and dimen-
sion a flowmeter for your specific
application.
Prowirl W (wafer)
Nominal
diameter
DIN
Air
(at 0 °C, 1.013 bar)
[m
3
/h]
Water
(20 °C)
[m
3
/h]
K-Factor
[pulses/dm
3
]
Q
min
Q
max
f-range (Hz) Q
min
Q
max
f-range (Hz) min/max
DN 15
DN 25
DN 40
DN 50
DN 80
DN 100
DN 150
0 4.0
10.6
27.7
44.3
102
171
379
25.4
150
394
630
1443
2432
5381
455.4...2903.5
183.6...2504.2
112.8...1586.9
87.4...1251.3
56.7...801.7
43.7...621.5
29.5...418.4
00.151
0.38
0.998
1.6
3.65
6.16
13.6
4.99
18.0
47.3
75.6
173
292
646
15.9...529.8
6.7...283.8
4.8...189.3
3.2...139
2.1...89
1.6...69.3
1.1...46.59
389.4...430.4
57.1...63.1
13.8...15.2
6.8...7.5
1.9...2.1
0.87...0.97
0.266...0.294
Nominal
diameter
ANSI (Sch 40)
DN 15
DN 25
DN 40
DN 50
DN 80
DN 100
DN 150
4.0
10.6
25.0
41.1
90.5
156
354
25.4
150
355
584
1287
2219
5036
455.4...2903.5
183.6...2504.2
121.5...1691.2
92.7...1314
60.5...858
46.2...657.7
30.6...434.2
0.151
0.380
0.898
1.48
3.26
5.62
12.8
4.99
18.0
42.6
70.1
154
266
604
15.9...526
6.3...278.8
4.3...188.2
3.3...146.3
2.2...95.3
1.7...73.2
1.1...48.3
389.4...430.4
57.1...63.1
16.3...18.0
7.7...8.5
2.3...2.5
1.014...1.12
0.295...0.326
Prowirl F (flange DN 15...150) / Prowirl H (high pressure DN 15...150)
Nominal
diameter
(all stan-
dards)
Air
(at 0 °C, 1.013 bar)
[m
3
/h]
Water
(20 °C)
[m
3
/h]
K-Factor
[pulses/dm
3
]
Q
min
Q
max
f-range (Hz) Q
min
Q
max
f-range (Hz) min/max
DN 15
DN 25
DN 40
DN 50
DN 80
DN 100
DN 150
3.94
8.8
21.6
36.1
81
140
319
24.9
125
308
513
1151
1994
4537
455.4...2903.5
196...2784.7
127.8...1813.8
95...1353.8
64.1...908.8
48...681.6
31.2...453.8
0.15
0.317
0.78
1.3
2.92
5.05
11.5
4.92
15.0
36.9
61.6
138
239
545
15.9...523.8
7.1...311.9
4.6...202
3.4...150.4
2.3...101.3
1.7...75.9
1.2...50.5
389.4...430.4
76.2...84.2
20.1...22.3
9.0...10.0
2.7...3.0
1.16...1.29
0.34...0.38
(The measuring ranges for DN 50 and DN 150 of the high pressure version differ
slightly from the given table values)
Prowirl F (flange DN 200...300)
Nominal
diameter
DIN
Air
(at 0 °C, 1.013 bar)
[m
3
/h]
Water
(20 °C)
[m
3
/h]
K-Factor
[pulses/dm
3
]
Q
min
Q
max
f-range (Hz) Q
min
Q
max
f-range (Hz) min/max
DN 200
DN 250
DN 300
627
1001
1414
8916
14218
20094
22.9...325.8
18.1...257
14.9...211
27.6
55.3
93.3
1070
1707
2412
1...36.2
1...28.6
0.98...23.5
0.125...0.138
0.0618...0.0683
0.0336...0.042
Nominal
diameter
ANSI (Sch 40)
DN 200
DN 250
DN 300
615
1000
1377
8743
14218
19575
22.5...329.2
17.3...263.9
14.5...219.7
26.8
55.5
89.7
1050
1707
2350
0.98...36.6
0.94...29.4
0.94...24.5
0.129...0.142
0.066...0.074
0.0372...0.0436