2.6 Technical data: Silometer FMC 671 Z/676 Z transmitter
Construction
Design: 19", 7 HP, plug-in card
Front panel: black synthetic with blue field inlay, grip and markings,
Protection: IP 20 (DIN 40050)
Dimensions: see diagram
Weight: approx. 0.3 kg
Operating temperature: –0°C...+70°C
Storage temperature: –20°C...+85°C
Electrical connection
Multipoint plug: conforming to DIN 41612, Part 3, Type F (28-pole)
- FMC 671 Z/676 Z with coding pins in positions 1 and 22
Power supply: 24 V DC (–4V+6V); residual ripple <600 mA, 100 Hz
Supply current: approx. 90 mA, max. 125 mA, integrated fine-wire fuse
Signal inputs: Electrically isolated from the rest of the circuitry
Protection [EEx ia] IIC or IIB
Probes, Channel 1: Capitance probes with EC 37 Z or EC 47 Z electronic insert
Deltapilot S DB with FEB 17 (P) electronic insert
Channel 2: Capacitance probes with EC 17 Z or EC 16 Z electronic insert
Liquiphant DL 17 Z or Soliphant DM 9092 Z.
Electromagnetic Interference Emission to EN 61326; Electrical Equipment Class A
compatibility: Interference Immunity to EN 61326
Outputs
Analogue output: 0...20 mA/4...20 mA selectable, R
L
max. 500
0...10 V/2...10 V selectable, R
L
min. 10 k
Relays: Two independent relays each with a potential-free
change-over contact; freely selectable switching range
and hysteresis
Third relay for fault indication
Max. switching capacity: 2.5 A, 250 V AC, 300 VA
at cos ϕ > 0.7
or 100 V DC, 90 W
Fail-safe circuit Minimum or maximum, switchable
Indication and
configuration
FMC 671 Z/676 Z: LCD and 6 buttons on front panel (FMC 671 Z only).
6 LEDs for function control, also configurable via
Commulog handheld terminal or ZA 672/ZA 67
FMC 676 Z: 6 LEDs for function control, also configurable via
Commulog handheld terminal or ZA 672/ZA 67 interface
Certificates
Silometer TÜV 0 ATEX 1640
FMC 671 Z/676 Z: PTB No. Ex-88.B.2048 X
BA063E22
Fig. 2.11
Silometer FMC 671 Z/676 Z
plug-in card
Silometer FMC 671 Z/676 Z Chapter 2: Installation