3.2 Operating elements: Silometer FMC 671 Z
Fig. 3.1 shows the LC-display with matrix of the Silometer FMC 671 Z, Fig. 3.3 its front
panel. Table 3.1 below describes the function of the operating keys.
Note!
Changes are not possible if the matrix has been locked (Section 4.6).
Non-flashing parameters are either read-only indications or locked entry fields.
Measured value display
of the 0/4...20 mA signal with
bar graph (%)
Limit relay LEDs
Red lit, relay de-energised
Green lit, relay energised
Parameter entry keys
Diagnosis sockets
Check 0/4
20 mA signal
here
Alarm relay LED
Lights on fault condition,
relay de-energises
Flashes on warning,
relay remains energised
Matrix selection keys
Commulog sockets
Green communications LED
Lights when
Matrix position
BA063E23
Fig. 3.3:
Front panel of the
Silometer FMC 671 Z transmitter
Keys Function
Matrix selection
Press V to select the vertical position
Press H to select the horizontal position
Press simultaneously to select the measured value field, V0H0
Parameter entry
The display jumps to the next digit position in the digital display.
The digit count can then be changed.
The selected digit position flashes.
To change the position of the
decimal point
, press down both
»
« and »+«. The decimal point moves 1 space to the right.
Changes the count of the flashing digit position by +1
Changes the count of the flashing digit position by –1
To e n t e r a
negative number
decrease the leftmost digit until a
minus sign appears in front of it
Press »E« to register entry.
Unregistered entries remain ineffective and the instrument will
operate with the old value.
+
+
Table 3.1:
Silometer FMC 671 Z
Parameter entry and display keys
Silometer FMC 671 Z/676 Z Chapter 3: Operating elements