EasyManua.ls Logo

Endress+Hauser silometer FMC 671 Z - 9 Trouble-Shooting; Faults and Warnings

Endress+Hauser silometer FMC 671 Z
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Trouble-Shooting
This Chapter contains the following:
Faults and warnings
Fault analysis
Simulation
Instructions for commissioning replacement probes and transmitters.
Repairs
9.1 Faults and warnings
Fault condition When the FMC 671 Z/676 Z transmitter recognizes a fault condition:
the red fault LED lights and the alarm relay trips.
the output current reverts to the status selected in field V0H7
the limit value relays assume fail-safe mode as specified in fields V1H3 and
V1H8.
A diagnostic message is given in Field V9H0:
The last diagnostic message is retained in V9H1.
This message can be cleared by pressing the »E« key.
If the power fails, all relays de-energise.
Warnings When the FMC 671 Z/676 Z transmitter has detected a warning:
the red fault LED flashes but the Silometer continues to measure
the alarm relay remains energised
the appropriate message is to be found in V9H0.
The error messages are listed in Table 9.1 in the order of their priority.
Table 9.2, trouble-shooting, indicates possible configuration errors for the Silometer
FMC 671 Z/676 Z.
Silometer FMC 671 Z/676 Z Chapter 9: Trouble-Shooting
50