EasyManua.ls Logo

EnerSys BA27-01 - Page 32

EnerSys BA27-01
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMPONENT MAINTENANCE MANUAL
BA27
24-01-01
This document contains Data controlled by the U.S. Export Administration Regulations. Diversion or use contrary to U.S. law is prohibited
hours. Allow the battery to stand open circuit for a
minimum of 4 hours before repeating steps (iv) and (v).
viii.) If the second discharge duration is still less than 8
minutes, recharge the battery in accordance with
paragraph H and follow the rejection procedure.
b.) Option 2 – Using a 30 Amp discharge unit
i.) Check the battery open circuit voltage.
ii.) Perform a discharge as received test; discharge battery
to 21.0 volts and record the results.
iii.) Recharge the battery in accordance with paragraph H.
iv.) Allow the battery to stand open circuit voltage for 4 hours
minimum.
v.) Discharge the battery at 30 Amps to an end voltage of
21.0 volts.
vi.) If a discharge duration of 2 minutes or greater is
achieved, then the battery has passed the test.
Recharge the battery in accordance with paragraph H
and return to service.
vii.) If the discharge duration is less than 2 minutes, recharge
the battery in accordance with paragraph H for 12 – 24
hours. Allow the battery to stand open circuit for a
minimum of 4 hours before repeating steps (v) and (vi).
viii.) If the second discharge duration is still less than 2
minutes, recharge the battery in accordance with
paragraph H and follow the rejection procedure.
Page 16
Mar 13/17

Related product manuals