Enfinity
PV inverter
Installation guide
www.enfinity.biz
EN
1000TL / 1650TL / 2200TL / 2800TL / 3300TL / 3680TL / 4400TL / 5000TL

Questions and Answers

  • B
    Benjamin DavisAug 11, 2025
    What to do if my Enfinity Inverter has Grid Faults?
    • J
      John BanksAug 11, 2025
      If your Enfinity Inverter shows a Grid Fault, first wait for one minute to see if the grid returns to normal. Ensure the grid voltage and frequency meet required standards. Check the grid connection, including wires and interfaces. Verify grid usability. Also, check if the panel’s open-circuit voltage is similar to or exceeds the maximum DC voltage. If DC injection is higher than the set value, wait one minute. Try disconnecting and reconnecting the PV (+) and PV (-) with the DC input.
  • C
    Chelsea BennettAug 16, 2025
    What to do if I see a Ground I Fault on my Enfinity 1000TL?
    • C
      Cory PenaAug 16, 2025
      If your Enfinity Inverter indicates a Ground I Fault, it could be due to high leakage current. Disconnect the DC and AC connectors and inspect the surrounding equipment on the AC side. Reconnect the input connector to check the inverter's status after troubleshooting.
  • E
    ebennettAug 22, 2025
    What should I do if my Enfinity Inverter shows High DC Bus?
    • C
      colemankayleeAug 23, 2025
      If your Enfinity Inverter displays a High DC Bus error, check the L and N lines for any connection faults.
  • A
    Anthony HigginsAug 28, 2025
    What should I do if my Enfinity 1000TL Inverter has an Isolation Fault?
    • N
      Nicole HancockAug 29, 2025
      If your Enfinity Inverter shows an Isolation Fault, disconnect the PV (+) and PV (-) from the DC input, and then reconnect them.
  • J
    Joan LopezSep 4, 2025
    What to do if my Enfinity Inverter is showing a Fan Fault?
    • D
      David Hunter DVMSep 4, 2025
      If your Enfinity Inverter is showing a Fan Fault, check the fan's wiring to ensure it is in normal condition.

Enfinity 1000TL Specifications

General IconGeneral
ModelEnfinity 1000TL
Rated Power1000 W
Max. DC Power1100 W
Max. DC Voltage500 V
Nominal AC Power1000 W
Output Voltage (AC)230 V
Rated Power Output1000 W
Output Voltage230 V
Frequency50/60 Hz
Number of MPPT Trackers1
CoolingNatural convection
Operating Temperature-25°C to +60°C