CCS3100
21
User Manual R0.2
Timing
34
ScrewPress Alarm
Screw Pressure Fail
Alarm Delay
0,0
30,0
3,0
sec
1
Timing
35
DeltaPress Alarm
Pressure Difference
Fail Alarm Delay
0,0
30,0
3,0
sec
1
Timing
36
Fan Working Time
Fan Maximum
Operation Time
0,0
1200,0
20,0
sec
1
Timing
37
Dryer Duration
Dryer Operation Time
0,0
60,0
50,0
min
1
Timing
38
Sufficiency
Pressure Difference
Alarm Delay Time
0,0
600,0
300,0
sec
1
Timing
39
Horn Duration
Horn Duration
10,0
999,0
60,0
sec
1
Inputs
42
Function
Input-1 Function
0
16
1
1: Emergency Stop
2
Inputs
43
Delay
Input-1 Function
Delay Time
0
30
0
sec
2
Inputs
44
Contactor
Input-1 Contact
Polarity
0
1
0
2
Inputs
46
Function
Input-2 Function
0
16
5
5: Motor Thermic
2
Inputs
47
Delay
Input-2 Function
Delay Time
0
30
3
sec
2
Inputs
48
Contactor
Input-2 Contact
Polarity
0
1
0
2
Inputs
50
Function
Input-3 Function
0
16
2
2: Seperator Filter
2
Inputs
51
Delay
Input-3 Function
Delay Time
0
30
3
sec
2
Inputs
52
Contactor
Input-3 Contact
Polarity
0
1
0
2
Inputs
54
Function
Input-4 Function
0
16
4
4: Phase Seq - DI
2
Inputs
55
Delay
Input-4 Function
Delay Time
0
30
1
sec
2
Inputs
56
Contactor
Input-4 Contact
Polarity
0
1
0
2
Inputs
58
Function
Input-5 Function
0
16
12
12: Custom - 1 Alarm
2
Inputs
59
Delay
Input-5 Function
Delay Time
0
30
3
sec
2
Inputs
60
Contactor
Input-5 Contact
Polarity
0
1
0
2
Inputs
62
Function
Input-6 Function
0
16
13
13: Custom - 2 Alarm
2
Inputs
63
Delay
Input-6 Function
Delay Time
0
30
3
sec
2
Inputs
64
Contactor
Input-6 Contact
Polarity
0
1
0
0: NO 1: NC
2
Inputs
66
Function
Input-7 Function
0
16
0
0: None
2
Inputs
67
Delay
Input-7 Function
Delay Time
0
30
0
sec
2
Inputs
68
Contactor
Input-7 Contact
Polarity
0
1
0
0: NO 1: NC
2
Inputs
70
Function
Input-8 Function
0
16
6
6: Fan Thermic
2
Inputs
71
Delay
Input-8 Function
Delay Time
0
30
0
sec
2
Inputs
72
Contactor
Input-8 Contact
Polarity
0
1
0
0: NO 1: NC
2
Output
74
Function
Output-1 Function
0
28
8
8: Fan
2
Output
75
Delay
Output-1 Function
Delay Time
0
30
0
sec
2
Output
76
Contactor
Output-1 Contact
Polarity
0
1
0
0: NO 1: NC
2
Output
78
Function
Output-2 Function
0
28
4
4: Load Valve
2
Output
79
Delay
Output-2 Function
Delay Time
0
30
0
sec
2
Output
80
Contactor
Output-2 Contact
Polarity
0
1
0
0: NO 1: NC
2
Output
82
Function
Output-3 Function
0
28
3
3: Delta Contactor
2
Output
83
Delay
Output-3 Function
Delay Time
0
30
0
sec
2
Output
84
Contactor
Output-3 Contact
Polarity
0
1
0
0: NO 1: NC
2
Output
86
Function
Output-4 Function
0
28
2
2: Star Contactor
2