EasyManua.ls Logo

Enko CCS 3100 - CCS3100 Parameter Categories; Maintenance, Temperature, and Mains Parameters

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CCS3100
22
User Manual R0.2
Output
87
Delay
Output-4 Function
Delay Time
0
30
0
sec
2
Output
88
Contactor
Output-4 Contact
Polarity
0
1
0
0: NO 1: NC
2
Output
90
Function
Output-5 Function
0
28
1
1: Main Contactor
2
Output
91
Delay
Output-5 Function
Delay Time
0
30
0
sec
2
Output
92
Contactor
Output-5 Contact
Polarity
0
1
0
0: NO 1: NC
2
Maintenance
98
General Maint.
Overall Maintenance
Time Set
200
30000
2500
h
3
Maintenance
99
Roller Maint.
Bearing Maintenance
Time Set
200
30000
20000
h
3
Maintenance
100
OilChange Maint.
Oil Change Service
Time Set
200
30000
5000
h
3
Maintenance
101
AirFilter Maint.
Air Filter Service
Time Set
200
30000
5000
h
3
Maintenance
102
OilFilter Maint.
Oil Filter Service
Time Set
200
30000
2500
h
3
Maintenance
103
SepFilter Maint.
Seperator Filter
Service Time Set
200
30000
5000
h
3
Maintenance
107
Maintaince Reset
Maintenance Time
Reset
0
6
0
0: None 1: General 2: Roller
3: OilChange
4: Air Filter. 5: Oil Filter 6:
Seperator Filter
2
Temperature
122
Temp1 High Alarm
Temperature-1 High-
Fail Alarm
-
200,0
200,0
100,0
C
1
Temperature
123
Temp1 High Warn
Temperature-1 High-
Warning Alarm
-
200,0
200,0
90,0
C
1
Temperature
124
Temp1 Low Alarm
Temperature-1 Low-
Fail Alarm
-
200,0
200,0
-20,0
C
1
Temperature
125
Temp1 Low Warn
Temperature-1 Low-
Warning Alarm
-
200,0
200,0
-10,0
C
1
Temperature
126
Preheat Limit
Preheat Temperature
Limit
-
200,0
200,0
10,0
C
1
Temperature
127
Temp1 SensorType
Temperature-1
Sensor Type Select
0
4
0
0: NTC 1: KTY81
2
Temperature
128
Temperature Unit
Temperature Unit
0
1
0
0: Degree 1:Fahrenayt
1
Temperature
129
Fan Start
Fan Start
Temperature Level
-
200,0
200,0
80,0
C
1
Temperature
130
Fan Stop
Fan Stop
Temperature Level
-
200,0
200,0
60,0
C
1
Temperature
131
Dryer Start
Dryer Start
Temperature Level
-
200,0
200,0
15,0
C
1
Temperature
132
Dryer Stop
Dryer Stop
Temperature Level
-
200,0
200,0
5,0
C
1
Temperature
134
Temp2 High Alarm
Temperature-2 High-
Fail Alarm
-
200,0
200,0
100,0
C
1
Temperature
135
Temp2 High Warn
Temperature-2 High-
Warning Alarm
-
200,0
200,0
90,0
C
1
Temperature
136
Temp2 Low Alarm
Temperature-2 Low-
Fail Alarm
-
200,0
200,0
-20,0
C
1
Temperature
137
Temp2 Low Warn
Temperature-2 Low-
Warning Alarm
-
200,0
200,0
-10,0
C
1
Temperature
138
Temp2 SensorType
Temperature-2
Sensor Type Select
0
4
0
0: NTC 1: KTY81
2
Temperature
139
Temp2 SensorMode
Temperature-2
Sensor Operation
Mode
0
2
0
0: Off 1: Normal 2: Difference
2
Temperature
140
Press Comp.Temp.
-
200,0
200,0
0,0
C
2
Temperature
141
Oil Freeze Prvnt
Oil Freeze Prevention
Temperature
-
200,0
10,0
-99,9
C
2
Mains
142
Unbalance
Mains Feed
Unbalance Value
0
100
20
2
Mains
143
Volt Low Alarm
Mains Feed Low-
Voltage Fail
0
600
310
V
2
Mains
144
Volt Low Warn
Mains Feed Low-
Voltage Warning
0
600
330
V
1
Mains
145
Volt High Alarm
Mains Feed High-
Voltage Fail
0
600
466
V
2
Mains
146
Volt High Warn
Mains Feed High-
Voltage Warning
0
600
450
V
1