Envoy Installation and Operation
2014 Enphase Energy Inc. 141-00011 Rev 05
59
Message Shown on
Events and Inventory
Screens
Description
Microinverter grid
configuration failure
cleared after xx attempts
Description: A failed attempt to change the grid profile for the microinverters has
cleared. The grid profile was successfully applied.
xx = number of attempts
Recommended Action: No action is required.
Module Sleeping
Description: The microinverter is off for the night.
Recommended Action: No action is required.
No Grid Profile
Recommended Action: Ask the installer to use the Envoy Gateway interface to
select a grid profile for this system. For more information, see “Change or View the
Grid Profile” on page 41
Description: The Envoy has not been set up with a grid profile for the
microinverters.
Over Temperature
Description: The microinverter is too hot and is not producing power. This very
rare condition usually clears without intervention.
Recommended Action: No action is required unless the condition persists. If it
persists, contact Enphase Energy customer support.
Power generation off by
command
Description: The microinverter is not producing power by user command. This
uncommon condition will occur only during isolated troubleshooting procedures by
Enphase personnel.
Recommended Action: No action is required.
Power On Reset
Description: The microinverter has powered on after having both AC and DC
disconnected.
Recommended Action: No action is required.
RGM Error
Description: The Enphase-compatible Revenue Grade Meter (RGM) has failed.
Recommended Action: Contact your installer to arrange for installation of a
replacement meter.
RGM Power Quality
Warning
Description: The Enphase-compatible Revenue Grade Meter (RGM) reports that
the AC voltage coming from the utility is either too low or too high as specified by
applicable regional standards. This is usually a temporary condition that will clear
when power quality from the local utility returns to normal.
Recommended Action: No action is required unless the condition persists. If the
condition persists, contact your installer.
Shutdown
Description: The Envoy has been powered down (unplugged from AC power).
Recommended Action: Restore AC power to the Envoy.
Startup
Description: The Envoy has been powered back up (plugged back in to AC
power).
Recommended Action: No action is required.
Transient Grid Profile
Recommended Action: No action is required. This condition will clear once the
grid profile test is complete.
Description: This system is currently in test mode.

Table of Contents

Other manuals for enphase Envoy

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the enphase Envoy and is the answer not in the manual?

enphase Envoy Specifications

General IconGeneral
ModelEnvoy
CategoryGateway
CompatibilityEnphase Microinverters
CommunicationWi-Fi, Ethernet
NetworkingIEEE 802.11 b/g/n
Operating Temperature-40°C to +65°C
Enclosure RatingIP30
Power Supply100-240 VAC
Power Consumption5W typical