IQ 7 / IQ 7+ / IQ 7X / IQ 7A Installation and Operation
© 2020 Enphase Energy Inc. All rights reserved. 141-00044-02
Enphase IQ7-60-2-INT Microinverter Parameters
Maximum3 microinverters per 20A (max) AC branch circuit
230 VAC
16 (single-phase)
48 (multiphase)
EN 50530 (EU) weighted efficiency
230 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Storage temperature range
Features and Specifications
Pairs with most 60-cell PV modules (the PV module DC
conductors must be labeled "PV Wire" or "PV Cable” to be
compliant for Ungrounded PV Power Systems)
Dimensions not including mounting bracket
212 mm x 175 mm x 30.2 mm (approximate)
MC-4 (or Amphenol H4 UTX with additional Q-DCC-5
adaptor)
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
• 6 mm mounting hardware: 5 N m
• 8 mm mounting hardware: 9 N m
• When using earthing hardware, use the manufacturer’s
recommended torque value
Natural convection - no fans
Approved for wet locations
AS 4777.2, RCM, IEC/EN 61000-6-3, IEC/EN 62109-1,
IEC/EN 62109-2
The DC circuit meets the requirements for ungrounded PV
arrays. Ground fault protection (GFP) is integrated into the
class II double insulated microinverter.
Enlighten Manager and MyEnlighten monitoring options
require an Enphase Envoy-S
The DC connector has been evaluated and approved for
use as the load-break disconnect.
The AC connector has been evaluated and approved for
use as the load-break disconnect.
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
.