IQ 7 / IQ 7+ / IQ 7X / IQ 7A Installation and Operation
© 2020 Enphase Energy Inc. All rights reserved. 141-00044-02
IQ7PLUS-72-2-INT Microinverter Parameters
Miscellaneous Parameters
Maximum6 microinverters per 20A (max) AC branch circuit
230 VAC (single phase)
13 (single-phase)
39 (multiphase)
EN 50530 (EU) weighted efficiency
230 VAC (single phase)
%
96.5
Static MPPT efficiency (weighted, ref EN 50530)
%
99.5
Total harmonic distortion
%
5
Ambient temperature range
C
-40
+65
Night tare loss
mW
50
Storage temperature range
C
-40
+85
Features and Specifications
Compatibility
Pairs with most 60 and 72-cell PV modules
Dimensions not including mounting bracket
212 mm x 175 mm x 30.2 mm (approximate)
Connector type
MC-4 (or Amphenol H4 UTX with additional Q-DCC-5
adaptor)
Weight
1.08 kg (2.38 lbs.)
Environmental category / UV exposure rating
IP67 / outdoor
Torque specifications for fasteners
(Do not over torque)
6 mm mounting hardware: 5 N m
8 mm mounting hardware: 9 N m
When using earthing hardware, use the manufacturer’s
recommended torque value
Cooling
Natural convection - no fans
Relative humidity range
4% to 100% condensing
Approved for wet locations
Yes
Pollution degree
PD3
Communication
Power line
Standard warranty term
enphase.com/warranty
Compliance
AS 4777.2, RCM, IEC/EN 61000-6-3, IEC/EN 62109-1,
IEC/EN 62109-2
Grounding
The DC circuit meets the requirements for ungrounded PV
arrays. Ground fault protection (GFP) is integrated into the
class II double insulated microinverter.
Monitoring
Enlighten Manager and MyEnlighten monitoring options
require an Enphase Envoy-S
Integrated DC disconnect
The DC connector has been evaluated and approved for
use as the load-break disconnect.
Integrated AC disconnect
The AC connector has been evaluated and approved for
use as the load-break disconnect.
6
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
.