IQ8MC/IQ8AC/IQ8HC Installation and Operation Manual
31 © 2023 Enphase Energy Inc. All rights reserved. September 2023
IOM-00029-1.0
IQ8HC-72-M-INT Microinverter parameters
Features and specifications
Compatibility
54-cell/108-half-cell, 60-cell/120-half-cell, 66-
cell/132-half-cell, 72-cell/144-half-cell
Dimensions (without mounting brackets) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)
DC connector type Stäubli MC4
Weight 1.1 kg
IP Rating Outdoor - IP67
Torque specifications for fasteners
(Do not over torque)
6 mm mounting hardware: 5 N m
8 mm mounting hardware: 9 N m
Cooling Natural convection - No fans
Relative Humidity range 4% to 100% (condensing)
Approved for wet locations Yes
Altitude < 2600 m
Pollution degree PD3
Standard Warranty Term http://enphase.com/warranty
IQ8HC-72-M-INT Microinverter parameters
Compliance
Grid compliance:
G98, G99, G100
Safety:
EN IEC 62109-1, EN IEC 62109-2
EMC:
EN IEC 61000-3-2, 61000-3-3, 61000-6-2,
61000-6-3, EN IEC 50065-1, 50065-2-1
EN55011 (At STC within MPP range)
Earthing
The DC circuit meets the requirements for
ungrounded PV arrays. Ground fault protection
(GFP) is integrated into the class II double-
insulated microinverter.
Monitoring
Enphase Installer Platform and Enphase App
monitoring options. Both options require an IQ
Gateway
Communication
Power line communication (PLC)