Setting Up the Matrix N7 Chassis
3-4 Matrix N7 Chassis Setup
3.2 SETTING UP THE MATRIX N7 CHASSIS
The following sections describe the procedures that must be followed to complete the installation 
of the Matrix N7 chassis.
3.2.1 Order of Installation
Once a suitable site has been chosen, the Matrix N7 chassis can be installed as a freestanding or 
rack-mounted unit.
It is recommended that the Matrix N7 chassis installation proceed in the following order:
1. Install the rubber feet (for freestanding installation) and cable management bar. (Section 3.2.2)
2. Mount the chassis to a 48.26-centimeter (19-inch) rack or other secure location. (Section 3.2.3)
3. Attach the Electrostatic Discharge wrist strap. (Section 3.2.3.3)
4. Install the power supply module(s). (Section 3.2.4)
3.2.2 Installing the Rubber Feet and Cable Management Bar
If you are installing the Matrix N7 chassis as a freestanding device, start with Section 3.2.2.1 to 
install the rubber feet. To install the chassis in a rack, rubber feet are not needed. Therefore, start 
with Section 3.2.2.2 to install the cable management bar.
CAUTION: Using longer screws than the ones packaged with the cable management 
bar may cause damage to the chassis. 
NOTE: Before installing the rubber feet and cable management bar, place the chassis 
on its back on a sturdy flat surface to have access to the bottom of the chassis.