19
ENVISION RESIDENTIAL INSTALLATION MANUAL
Horizontal Dimensional Data
2ft [61cm]
Primary Service Access
B
C
2.1in [5.4cm]
H
L
O
N
M
S
R
Q
P
MOUNT (2) HANGER BRACKETS
AS SHOWN TO ALLOW ACCESS
TO FILTER
AS SHOWN LR UNIT (RR UNIT ON OPPOSITE SIDE—SAME DIMENSIONS)
SIDE DISHCARGE VIEW
END VIEW
TOP VIEW
A
S
FRONT VIEW
DEFG
KJI
1.9in
[4.8cm]
O
L
Overall Cabinet
Water Connections Electrical Knockouts
Return Connection
Horizontal
DEFGH
IJK
using std deluxe filter rack (±0.10 in)
Models
ABC
Loop
1/2" cond 1/2" cond 3/4" cond LMNOPQRS
Width Depth Height* In Out HWG In
HWG
Out
Cond-
ensate
Water FPT HWG FPT
Low
Voltage
Ext Pump
Power
Supply
Supply
Height
Supply
Depth
Return
Depth
Return
Height
022-030
in. 22.5 63.0 19.3 2.0 7.0 13.5 16.5 0.8
1" Swivel 1" Swivel
8.89.4 11 .8 2.3 10.5 9.4 5.8 2.8 30.516.9 1.3
cm. 57.2 160.0 49.0 5.0 17.7 34.2 41.8 2.1 22.2 24.0 30.05.8 26.5 23.8 14.7 7.0 77.342.9 3.3
036-038
in. 25.6 72.0 21.3 2.3 7.3 15.9 18.9 0.8
1" Swivel 1" Swivel
8.89.4 11 .8
SEE
CHART
SEE
CHART
SEE
CHART
SEE
CHART
SEE
CHART
SEE
CHART
13.6 13.2 2.8 35.518.9 1.3
cm. 65.0 182.9 54.1 5.7 18.4 40.3 47.9 2.1 22.2 24.0 30.0 34.6 33.5 7.0 90.047.9 3.3
042-049
in. 25.6 77.0 21.3 2.3 7.3 15.9 18.9 0.8
1" Swivel 1" Swivel
8.89.4 11 .8 13.6 13.2 2.8 40.418.9 1.3
cm. 65.0 195.6 54.1 5.7 18.4 40.3 47.9 2.1 22.2 24.0 30.0 34.6 33.5 7.0 102.5 47.9 3.3
060-072
in. 25.6 82.0 21.3 2.3 7.3 15.9 18.9 0.8
1" Swivel 1" Swivel
8.89.4 11 .8 13.6 13.2 2.8 45.418.9 1.3
cm. 65.0 208.3 54.1 5.7 18.4 40.3 47.9 2.1 22.2 24.0 30.0 34.6 33.5 7.0 115.2 47.9 3.3
Rev.: 07/18/06 B
Discharge Connection
duct flange installed (±0.10 in)
Condensate is 3/4" PVC female glue socket and is switchable from side to front
Horizontal unit shipped with deluxe 2" (field adjustable to 1") duct collar/filter rack extending from unit 2.88" and is suitable for duct connection.
Discharge flange is field installed and extends 1" [25.4 mm] from cabinet
Decorative molding and water connections extend 1.2" [30.5mm] beyond front of cabinet.
LUnits Not Shown Above O
in. 2.8 4.6
cm. 7.1 11 .8
in. 4.9 6.9
cm. 12.4 17.5
in. 4.9 7.6
cm. 12.4 19.4
in. 2.8 6.9
cm. 7.1 17.5
Right Return End Discharge
Right Return Side Discharge
Left Return End Discharge
Left Return Side Discharge