EasyManua.ls Logo

EOGB X400 - Technical Specifications - Overview; Technical Data; Burner Dimensions

EOGB X400
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL SPECIFICATIONS
Technical Data
Model X400 X500 X600
Burner output Min kW 14 30 58
Max kW 50 70 130
Fuel Flow rate Min Kg/h 1.2 2.5 4.8
Max Kg/h 4.2 5.8 10.8
Fuel Kerosene
Gas Oil
Max viscosity 5.5cst @ 20ºC
Electrical supply V 230V ±10% 50Hz 1 phase
Motor W 90 90 130
Transformer 40mA (rms) 15kV
Current Start A 1.60 1.60 2.20
Run A 0.53 0.53 0.87
Weight kg 9.2 9.2 9.5
Mode of operation On/off
Burner Dimensions (mm)
Model
root
max
B* C D E F G H J K L
X400-1N 89 89 73 231 50 161 194 138 268 90 125-150 10
X400-2N 89 89 73 231 50 161 194 138 268 90 125-150 10
X400-1 89 89 73 231 50 161 194 138 297 90 125-150 10
X400-2 89 89 73 231 50 161 194 138 297 90 125-150 10
X500-1 89 89 73 231 50 161 204 204 318 90 125-150 10
X500-2 89 89 80 231 50 161 204 204 318 90 125-150 10
X600-1 89 89 80 231 50 161 204 204 360 90 125-150 10
X600-2 89 109 120 231 50 161 204 204 360 90 125-150 10
*Standard lengths only - other lengths are available.
E90-803-001-001-00 - 02/06