BURNER INSTALLATION
Mounting onto the appliance
The burner is mounted onto the appliance by means
of a removable 6-bolt flange.
The gasket needs to be put in place before the flange
is fixed onto the appliance. The burner tube is then
inserted through the centre hole.
With the burner rotated a few degrees clockwise the
flange bolts will pass through the locating holes. When
the burner is twisted into position the top bolt can then
be tightened to secure the burner. If necessary the
lower screw can be adjusted to give a more secure
fixing.
If required the burner can be mounted in any position.
It is important though to ensure that the solenoid valve
on the oil pump is not inclined below horizontal.
Air Intake Device
The burner is supplied with an air intake device
that can be rotated through 180º to allow the air
to be taken from a position suitable within the
appliance housing.
The intake has a 60mm diameter entry to allow a
snorkel tube, as used on some balanced flue
units, to be connected. There is a grill fitted to
the entry that can be removed if required.
Top
locating
hole
Bottom
locating
cut-out
Tube Adapter
An intake adapter is
available fo
r
applications
equipped with
70mm diameter ai
r
tubes.
For the part numbe
r
see pages 10 and 11
for details.