Loading...
2
Local temp. sensor
Measure ambient temperature.
For battery 1
Indicate battery #1 charging status and error.
For battery 2
Indicate battery #2 charging status and error.
Remote meter
connection
Connect with a remote meter.
Note: No RTS; the controller measures ambient temperature by the local
temp. sensor. While the controller will obtain data from the RTS
automatically after the RTS is connected.
EPIPDB-COM series are common-negative controllers. Negative terminals
of the PV array and batteries can be grounded simultaneously, or any
negative terminal is grounded. According to the practical application, the
negative terminals of the PV array and batteries can also be ungrounded.
However, the grounding terminal on the controller shell must be grounded.
It can shield electromagnetic interference and avoid electric shock to the
human body.
Using a common-negative controller for common-negative
systems, such as the RV system, is recommended. The
controller may be damaged if a common-positive controller
is used and the positive electrode is grounded in the
common-negative system.
2. Mode setting
Three LEDs flash, and each LED indicates different specifications. Choose

Related product manuals