6
Operation Steps:
Step 1: Turn the power switch of the inverter to OFF
Step 2: Disconnect the input breaker or the fuse between inverter
and battery, connect the battery terminals (+ with red line and -
with black line). Do not connect the poles by contraries.
Step 3: Use the cable no less than 4mm
2
to connect the grounding
terminal of the inverter to the ground.
Step 4: Connect the plug of AC load to the inverter AC outlet
Step 5: Switch on the input breaker or the fuse between inverter
and battery; turn on the power switch to start the inverter. If the
green indicator is on solid, turn on the loads one by one. Check the
operation state of the inverter and loads.
Step 6: If there are different types of loads, it is suggested that turn
on the loads with higher startup current first, such as television,
then after the loads works stably, turn on the loads with lower
startup current, such as incandescent lamp.
Step 7: If the Fault indicator is red and the buzzer alarms when turn
on the devices, please switch off the loads and inverter
immediately.
Note: When use USB port for charging, it is suggested
to charge the power bank first, and then use the power
bank to charge mobile phones.