When the default battery type is selected, the battery voltage parameters cannot be
modified. To change these parameters, select the "USE" type.
When the battery type is "USE," the battery voltage parameters follow the following logic:
A. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost
Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage.
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.
D. Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage≥ Discharging Limit Voltage;
E. Boost Reconnect Charging voltage >Low Voltage Reconnect Voltage.
⑤ Lithium Battery voltage parameters