Safety and operating instructions
28 © Anbaufräsen PC GmbH | 3390 5221 01 | 2020-09-07
Original Instructions
n
Let your assistant instruct you until the bores in the
adapter plate(C) and in the stick(D) are properly
aligned.
n
Install the stick bolt(E) and lock it.
D
E
C
n
Lift the hydraulic attachment.
D
G
C
F
n
Extend the bucket cylinder until the bore in the link-
age(G) links up with the bore in the adapter
plate(C).
n
Install the linkage bolt(F) and lock it.
n
Carefully move the bucket cylinder into both end po-
sitions.
The adapter plate must not be stopped by mechanical
stops in either position. Consult the authorized Customer
Center / Dealer in your area if the adapter plate is
stopped by a mechanical stop.
5.4.2 First installation
WARNING Risk of death due to defective first in-
stallation
Faults during the first installation or commissioning can
lead to life-threatening situations and may cause consid-
erable damage to property.
u Have the first installation exclusively conducted by
authorised specialist personnel.
u Do not undertake unauthorised first installation.
WARNING Unexpected movement
Sudden movements of the carrier may cause serious in-
jury.
u Secure the carrier such that it cannot move unex-
pectedly.
u Observe the carrier manufacturer’s instructions.
NOTICE Damage due to incorrect oil pressure setting
Incorrect oil pressure setting can result in severe dam-
age to property and the environment.
u Before installing the hydraulic attachment to the car-
rier check the oil pressure setting of pressure line
with a hydraulic flow tester.
u Check the tank line pressure with an additional
manometer mounted between hydraulic flow tester
and tank line.
u Ensure the technical specifications are fulfilled (see
chapter Technical specifications).
Filling hydraulic motor
Note: Prior to first commissioning the hydraulic motor of
the drum cutter must be filled with hydraulic oil (see
chapter Technical specifications).
Install separate leakage oil line
The separate leakage oil line including separate leakage
oil filter must be installed from the shut-off valve on the
boom to the carrier's hydraulic oil tank. The operator
must pre-install a suitable connection on the carrier's hy-
draulic oil tank for the leakage oil line.