Safety and operating instructions
66 © Anbaufräsen PC GmbH | 3390 5221 01 | 2020-09-07
Original Instructions
8.9 Overpressure cover for the hydraulic motor deformed, oil leak on
sealing surface, oil leak at the pressure limiting valve
Cause Remedy By
Pressure in the leakage oil line too
high. Leakage oil line not installed sep-
arately, leakage oil filter not main-
tained, shut-off valve in the leakage oil
line closed, plug coupling not correctly
latched.
Install leakage oil line as per hy-
draulic installation version 1 or 2 and
measure oil pressure.
Workshop
8.10 Oil leaking at the cutter drum area
Cause Remedy By
Slide ring seals on output shaft dam-
aged / high pressure seal between hy-
draulic motor and gear leaking
Change set of slide ring seals.
Change high pressure seal between
hydraulic motor and gear.
Authorized Customer Center / Dealer
in your area
8.11 Behaviour following fault elimination
After correcting the fault execute the following steps to start up again:
1.
Reset the emergency stop devices.
2.
Acknowledge the fault on the controller.
3.
Ensure that no one is present in the hazardous area.
4.
Start in accordance with the instructions in the chapter Preparations before starting.