SmartROC T35/T40 5 Safety Functions
25 No: 5966599819.1.5966707083 en-US
!
NOTE: The fire extinguisher at the rear of the machine is only available on models with
installed power higher than 200 kW. The fire extinguisher is on the left or right side, de-
pending on the specifications and equipment of the machine.
5.4.5 In Case of Fire - Fire Extinguisher
!
NOTE: Obey local regulations in case of fire.
Precondition
p
Parking brake is applied.
1.
Use a handheld fire extinguisher to extinguish the fire. Follow the manufacturer's in-
structions.
2.
Do the following steps only if this does not jeopardize your safety:
a.
Turn off the main power switch and the battery isolation switch, or whichever is
present on the machine.
b.
Close the fuel supply valve, if present.
!
NOTE: Do not restart the machine until the cause of the fire
has been established and faults have been corrected.
3.
Replace used fire extinguishers with approved new extinguishers.
4.
Clean out any extinguisher residue in the machine before operation.
5.4.6 Actions after Fire
!
NOTE: Restart the machine only when the cause of fire has been established and all
faults have been corrected.
Precondition
p
Handheld fire extinguishers have been used.
1.
Replace used fire extinguishers with approved new extinguishers.
2.
Inspect the firefighting equipment.
3.
Replace damaged parts on the machine.
4.
Clean out any extinguisher residue in the machine before operation.
Contact Epiroc
Contact an Epiroc local customer center for further information.