2016/09/02
Revision: 1 Page: 42
If 0 ≤ counter ≤ 127, then the data following the counter is non-compressed data, and
the length of the compressed data is (counter)+1 bytes.
If 128 ≤ counter ≤ 255, then the data following the counter will be one byte of
compressed data, . This single compressed byte of data is thereafter to be
repeated 257-(counter) times..
3) This function also increments the X printing position relative to the current X printing
position by the amount: (256 x nH + nL) x h/3600 x 25.4mm.
If this command specifies an X position in the non-printable area (right margin), the right
margin position is automatically reset to the X value of the new printing position.
4) If image data is designated for a non-printable area, then the image data designated for that
area is ignored.
The following parameter combinations are supported by this command:
These printers doesn’t have printer microweave mode.
1. Case of non-microweave mode
Mode Parameter ESC(e Used Nozzle number
(V x H) c v h m d
360x360 0/1/2 10
10
1/8/24 00h 180Nozzles
2. Case of printer microweave mode
No support.
*1 In these circumstances, it is recommended that m be set equal to 1.
*2 Whenever the ESC . command is used, the Normal (ESC ( e 2 0 0 0)) size must be selected.
[Initial State] Character mode
[Related Commands]
[Setting] Commands whose settings are affected by this command.
None
[Setting] Commands that change the effects of this command.
None
[Operation] Commands whose functionality is affected by this command.
None
[Operation] Commands that change the effects of this command.
None