Replacing the Lamp 63
9. Replace the lamp cover and tighten the screw. (The projector won’t work if the lamp
cover is open or loose.)
10. Reset the lamp usage timer, as described below.
Resetting the Lamp Usage Timer
After replacing the lamp, plug the projector back in and press the Ppower button. Then
follow these steps to reset the lamp usage timer:
1. Press the
Menu button on the projector or remote control.
2. Use the menu navigation buttons to open the
Reset menu, then select Reset Lamp
Hours
.
3. When you see a confirmation prompt, highlight
Yes and press the enter button.
4. When you’re finished, press the
Menu button to exit.
The lamp usage timer shows 0H until you’ve used the lamp for at least 10 hours.