Maintenance 2. Regular Maintenance Inspection
6 RC90 Series Maintenance Rev.1
2. Regular Maintenance Inspection
Performing regular maintenance inspection properly is essential for preventing trouble and
maintaining safety. This chapter describes the schedules for maintenance inspection and
procedures.
Be sure to perform the maintenance inspections in accordance with the schedules.
You will need following tools for maintenance inspection.
Phillips screwdriver
Slotted head screwdriver
Nut driver
Plier
Needle-nose plier
Nipper
Tester
2.1 Inspection Point and Frequency
Inspection Point
Frequency
Method
Check Item
Controller
12 months
Turn ON/OFF motor and Restart
Activates without any error
Emergency Stop Button 12 months
When the motor turned on,
activate the emergency stop button
Turns off the motor
Safeguard 12 months
When the motor turned on,
turn on the safeguard
Turns off the motor
Fan Filter
1 months
Visual inspection and cleaning
No stain
Fan
1 months
Checking the operating sound
No noise
Battery
12 months
Visual inspection of seven-segment and
LED
No alarm occurred
2.2 Timing of Replacement
Part Frequency Parts Code
Working Time
(Rough)
Reference
Fan Filter
4 years or deteriorated
2195107
5 min.
8.1 Fan Filter
Fan
Error 515 occurred or noise
2157260
20 min.
8.2 Fan
Battery
Every 5 years or error 511 occurred
2113554
15 min.
8.3 Battery

Table of Contents