EasyManua.ls Logo

Epson RC90 Series - EUROMAP67 Board

Epson RC90 Series
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance 7. Option Parts Replacement Procedures
36 RC90 Series Maintenance Rev.1
7.2 EUROMAP67 Board
For the detail of the board, refer to the RC90 Series Manual.
(1)
Turn OFF the Controller.
(
2)
Disconnect the power plug.
(
3)
Remove the Top Panel. (Mounting screw
×10)
(
4)
Insert the EUROMAP67 board into slots.
(
5)
Use four screws to fix the EUROMAP67 board in
place.
First, temporarily fasten the four screws in place.
Next, fully tighten screws located diagonally
opposite each other.
Take care not to damage the thread holes when
doing so.
(
6)
Connect “Cable1 CN2”.
Use a cross
-point screwdriver to fasten the
connector (CN2).
Connect
Cable1 to emergency stop connector.
(
7)
Refer to the following to connect CN3 to the
emergency stop switch (emergency stop, safety
door, latch).
RC90 Series Manual 11. EMERGENCY
(8)
Connect “CN3”.
Use a
cross-point screwdriver to fasten the
connector (CN3).
(9)
Connect “Cable2 CN1”.
Use a cross
-point screwdriver to fasten the
connector (CN1)
.

Table of Contents