Maintenance 8. Maintenance Parts Replacement Procedures
RC90 Series Maintenance Rev.1 41
8.3 Battery
CAUTION
■
meticulous care when handling the lithium battery. Improper handling of
the lithium battery as mentioned below is
extremely hazardous, may result in
leakage, explosion, or inflammation, and may cause serious
Disassembly
Incorrect Installation
Exposing to Fire
Forced Discharge
・Deformation by Pressure
・
Short-circuit (Polarity; Positive/Negative)
Heating (85°C or more)
Soldering the terminal of the lithium battery directly
■
battery supplied as maintenance part from EPSON.
r to 11. Maintenance Parts List.)
■
When disposing of the battery, consult with the professional disposal services or
comply with the local regulation.
Spent battery or not, make sure the battery terminal is insulated. If the terminal
contacts with the other metals, it may short and resul
t in heat generation,
leakage, explosion, or inflammation.
urn ON the Controller for approximately one minute before replacing the battery.
the replacement within 10 minutes to prevent data loss.
al
Backup the Controller data.
to 4. Backup and Restore.
Disconnect the power plug.
the Top Panel.
For LS3-B, LS6-B: Mounting screws ×10
For LS10-B, LS20-B, LS6-B602S-V1: Mounting screws ×6
Disconnect the battery cable.
the battery straight upward.