Maintenance 8. Maintenance Parts Replacement Procedures
52 RC90 Series Maintenance Rev.1
DPB
Installation
(1)
Inset the
DPB to the Controller.
(2)
Mount the
DPB.
For LS3-B, LS6-B:
Mounting screws × 9
For LS10-B, LS20-B, LS6-B602S-V1:
Mounting screws × 12
(3)
Only for
LS10-B, LS20-B, LS6-B602S-V1.
M
ount the rear plate on the Controller.
Mounting screws × 7
(4)
Connect the connectors to the DPB.
For LS3-B, LS6-B
: Connectors × 6
For LS10-B, LS20-B, LS6-B602S-V1
: Connectors × 8
(5)
Mount
the MDB.
Refer to : 8.5 MDB
(6)
Mount the Top Panel.
For LS3-B, LS6-B: Mounting screws ×10
For LS10-B, LS20-B, LS6-B602S-V1: Mounting screws ×6
(7)
Connect the power plug. Turn ON the Controller and make sure
that the
Controller
starts properly without any vib
ration or abnormal noise.