6. Absolute Maximum Ratings
Table 2 Absolute Maximum Ratings
GND=0V
When stored separately,
without packaging
7. Recommended Operating Conditions
Table 3 Recommended Operating Conditions
Unless otherwise specified, V
BAT
= V
DD
= V
IO
= 1.6V 5.5 V, Ta = -40
V
OUT
low detection Voltage
V
CLK
: Min. is available by initializing in V
DD
V
DET1
.
When first Power ON, for internal initializing, V
DD
must be more than 1.45V: +V
DET1
.
8. Frequency Characteristics
Table 4 Frequency Characteristics
Unless otherwise specified, V
BAT
= V
DD
= V
IO
= 1.6V 5.5 V, Ta = -40
A : 11.5 *1
B : 23.0 *2
Frequency/voltage
characteristics
Ta = +25 C
V
DD
= 1.1 V 5.5 V
Frequency/
Temperature
characteristics
Ta = −20 C +70 C
V
DD
= 3.0 V; +25 C reference
Oscillation
Start-up time
Ta = +25 C, V
DD
= 3.0 V;
First year
1
Equivalent to
60 seconds per month deviation.
2