Chapter 2 Preparing the setting file
21
2
ServerDirectPrint Interval Designates the standby time from the complete acquisition
of print data until the next acquisition process.
Integer from 1 to 86,400.
StatusNotification
Delete this item if you are not using the status notification.
Use Designates whether to enable / disable the Status
notification function.
“Enable” / “Disable”
ID Designates the ID used when notifying the server of the
status.
This must be set if the value for "Use" is "Enable".
Within 30 alphanumeric characters (only underscores,
periods, and hyphens)
Null characters can also be designated.
Password Designates the password used when notifying the server of
the status.
This must be set if the value for "Use" is "Enable".
Within 30 alphanumeric characters (only underscores,
periods, and hyphens)
Null characters can also be designated.
URL Designates the URL to send the status notification to.
This must be set if the value for "Use" is "Enable".
Within 255 alphanumeric characters.
The protocol is in http or https format.
Interval Designates the wait period from when a status is notified to
the next notification operation.
This must be set if the value for "Use" is "Enable".
Integer from 1 to 86,400.
Time Delete this item if not synchronizing with TimeServer.
UseTimeServer Designates whether to perform synchronization with
TimeServer or not.
“Enable” / “Disable”
TimeServer Designates the TimeServer name.
If the value for "UseTimeServer" is "Enable", this must be set.
Within 250 alphanumeric characters.
Timezone Designates the timezone.
You can acquire a list for the timezone ID using "Libtime get
time list".
Timezone ID defined for each OS / locale
DaylightSavingTi
me
Designates whether there is daylight saving time or not.
If "Timezone" is not designated, this is ignored.
“Enable” / “Disable”
Section name Parameter
Description
Valid value