Alarm Lists
Alarm Description Port Number Alarm ID Source Severity
OP-47 not detected on input
OP-47 data extraction is on but no
OP-47 data is present
1 010C4010 VBI minor
Max ANC Data Rate Exceeded
The maximum bit-rate of the generic
ANC data output is exceeded. A
lower input ANC data rate is
required.
1 010C4011 VBI warning
VPS not detected on input
Unable to find VPS data on any
of the configured lines. Please
check the video input. For more
details on the type of VBI, see
the VBI status page
1 010C4012 VBI minor
Video 1 Encode Invalid
Configuration
An invalid configuration has been
applied to Main Channel. Check
Video Standard and Profile
selection.
0 010C4018
CE-x
Analogue
minor
Reflex PCR Exchange Timeout
PCR Exchange message not
received within timeout period
1 010C4020
CE-x
Analogue
Module
warning
Reflex SetRate Msg Timeout
Set Rate message not received
within timeout period
1 010C4021
CE-x
Analogue
Module
warning
Reflex Apply-Time out of range
Set Rate message received that is
too late to be applied, or is more
than 5 seconds early. The alarm is
cleared by the reception of a valid
Set Rate message, or Reflex being
disabled
1 010C4022
CE-x
Analogue
Module
warning
Reflex Source Identifier
Unstable
The online source identifier has
changed twice in the last three
messages received
1 010C4023
CE-x
Analogue
Module
warning
Reflex Source Identifier
Mismatch
The online source identifier in the set
rate messages does not match the
source identifier in the pcr exchange
messages. (The alarm is only raised
if this has occurred in two
consecutive PCR exchange
messages)
1 010C4024
CE-x
Analogue
Module
warning
Reflex Tracking PCR Exchange
Timeout
PCR Exchange message not
received from online encoder within
timeout period
1 010C4025
CE-x
Analogue
Module
warning
Audio Module Error
The audio module reported an
unexpected status value.
0 010C3FE0
Audio
Module 1
minor
Audio Module CPU loading
The audio module CPU load is too
high to support the current audio
configuration.
0 010C3FE1
Audio
Module 1
major
Audio DSP Failed to Boot The audio DSP has failed to boot 0 010C3FE2
Audio
Module 1
major
Audio 1 Input lock
No valid audio detected on selected
input. Please check source
connection.
0 010C2000 Audio 1 major
Audio 1 TS input error
Incoming transport stream error.
Please check source TS.
0 010C2001 Audio 1 major