Replacing Main Unit
Ge2723A
1
2
5. Disconnect the internal RJ-45 cable from the GPS receiver unit.
Ge2717B
Port 1
6. Unscrew the internal coax cable from the ANT port on the GPS receiver
unit, and disconnect the cable.