38
SHIELD START
CUT START
SHIELD
CUT AIR
CUT OXYGEN / NITROGEN
START GAS
SHIELD GAS
CUT GAS
GAS PRESSURE
GAS PRESSURE
SECTION 4 OPERATION
4.2.2 Remote Setup Pendant
4.2.3 Remote Setup Panel
Remote setup pendant switch is identical in function to the Gas Test Switch on the
console.
Pendant has a three position switch:
Position CUT – Temporarily allows cut gas to ow to preset pressure before operation.
Cut gas pressure is displayed on the top digital meter.
Position START/SHIELD – Temporarily allows start and shield gases to ow before op-
eration. Start gas pressure is displayed on the top digital meter. Shield gas is displayed
on the bottom digital meter.
Position OPERATE – This is default position (Spring tension returns toggle to this posi-
tion). Switch will return to this position without assistance when released. This middle
switch position allows console to be in cutting mode (not setup).
The Remote Setup Panel is an option for Avenger 1 CNC cutting
machines and larger. It is substituted for the pendant and oper-
ates the same with addition of a regulator for cut oxygen and
nitrogen.
Refer to your cutting machine manual for details.