EasyManuals Logo

ESAB PowerCut 1600 Service Manual

ESAB PowerCut 1600
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #164 background imageLoading...
Page #164 background image
10
164
SECTION 9 GENERAL INFORMATION
10.0 GENERAL INFORMATION
10.1 Maintenance
VOLTAGES IN PLASMA CUTTING EQUIPMENT ARE HIGH ENOUGH TO CAUSE
SERIOUS INJURY OR POSSIBLY DEATH. BE CAREFUL AROUND EQUIPMENT
WHEN THE COVERS ARE REMOVED.
A maintenance schedule should be created and based on the following variables, amount of usage, place-
ment of machine and cleanliness of local environment. A maximum time between should be no more the
90 days.
External:Checkworkcableforworninsulationandconrmtightelectricalconnections.Checksafety
groundgroundatworkpieceandatpowersource.Checktorchcablesforworninsulationandconrmtight
electricalconnections.Drainanymoisturefromthebowloftheinputlter/regulator.
Internal:Checkfordiscoloredconnectionsastheyindicatealooseconnection.Checkallplugs,ttings
andelectricalconnectionsfortightness.Makesurecablesandhosesarenotdamaged,attenedorkinked.
With input power disconnected and wearing proper eye and face protection, blow out accumulated dirt and
foreignmaterialsfortheinsideofunit.Extraattentionshouldbegiventothennedheatsinks.
Water or oil occasionally accumulates in compressed lines. Be sure to direct the rst blast of air
away from the equipment to avoid damage to the EPP400

Table of Contents

Other manuals for ESAB PowerCut 1600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ESAB PowerCut 1600 and is the answer not in the manual?

ESAB PowerCut 1600 Specifications

General IconGeneral
BrandESAB
ModelPowerCut 1600
CategoryWelding System
LanguageEnglish

Related product manuals