630298_3 EF5000 Installation Guide - US
- Within a partial enclosure that includes an overhead cover and no more than two
walls.
- Within a partial enclosure that includes an overhead cover and more than two
walls, the following shall apply:
At least 25% of the total wall area is completely open, and
At least 30% of the remaining wall area is open and unrestricted
Rectangular areas have been used in the above diagrams, the same principles apply to any
other shaped area.
In the case of balconies, at least 20% of the total wall area shall be and remain open and
unrestricted.