Universal interface
ET System electronic GmbH 17
Response String
The response string has the following format:
command comma value unit <CR> <LF>
The value is a floating point string with a .‘ as delimiter.
Command
Response
Command
Response
IA
IA,12.34A
MU
MU,10.0V
LIMU
LIMU,500V
UA
UA,100V
LIMI
LIMI,30.00A
OVP
OVP,600V
Example: Command as ASCII and HEX protocol
L
I
M
U
,
5
0
0
.
0
V
4C
49
4D
55
2C
35
30
30
2E
30
56
0D
0A
The digits after the decimal point correspond to the resolution of the unit.
Example
UA at a 600 V unit UA,123.0V
UA at a 50 V unit UA,23.44V
The digits before the decimal point depend on the present measurement value.
Example: 600 V unit
UA,10.0V
UA,220.0V
UA,1.0V
Example: 50 V unit
UA,1.23V
UA,10.47V
UA,0.01V