ETC Installation Guide
ColorSource CYC v1.6
ColorSource CYC v1.6 Page 10 of 12 ETC
Error codes
There are three error codes that may be shown on the user interface.
• : Screen toggles between and to indicate a problem
with the color calibration. The fixture will need to be returned to the
ETC factory; contact your local dealer to set up a repair.
•
: Screen toggles between and to indicate that the
fixture has gone into over-temperature protection mode to avoid
damaging the fixture. Once the fixture has self-cooled, the error will
automatically clear.
•
: Screen toggles between and to indicate that the
upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.
RDM values
Manufacturer ID: 0x6574 (Electronic Theatre Controls)
Model ID: 0x0215 (ETC ColorSource CYC)
Parameter RDM PID Value
DMX Start
Address
0x00F0 Range = 1–512
Personality ID 0x00E0
1 = 5 Channel
2 = Direct
3 = 1 Channel
4 = RGB
Output
Frequency
0x8123
0 = Standard (1.2 kHz)
1 = High (25 kHz)