System Manual Safety System MGB-AR in Combination with a Locking Module
12
Changing Actuating Direction for Doors Hinged on the Left
Important!
It is only possible to make this change when the bolt tongue is not extended and
an escape release is not yet mounted.
As supplied, the handle module is set for doors hinged on the right.
The safety guard opens by pressing down the door handle.
The system is mounted the other way up for doors hinged on the left.
The safety guard opens by pressing up the door handle (see Figure 9).
For this reason the actuating direction of the door handle must be changed (see
Figure 9 - 14).
3
2
4
5
4
Lift locking pin on the door handle using a screwdriver and
hold in this position.
5
Turn door handle to right.
1
Push door handle upwards.
2
Unscrew locking pins to the marking
3
Push cover to the side.
7
a
6
b
4 mm
8
6
Only on the usage of an escape release: Turn joint with hex
screw counter-clockwise from position (a) to position (b).
7
Close cover.
8
Screw in locking pins and tighten to 2 Nm.
Figure 9: Changing actuating direction, step
1
Figure 10: Changing actuating direction, step
2
and
3
Figure 11: Changing actuating direction, step
4
and
5
Figure 12: Changing actuating direction, step
6
to
8