EasyManua.ls Logo

Evco EVDRIVE03 - Page 72

Evco EVDRIVE03
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.6 | Code 144EPDE364
page 72 of 76
signalling LEDs.
128 x 64 pixel
single colour
(black with
rearlighting
through white
LEDs) LCD
graphic
display,
signalling
LEDs.
Digital outputs:
1 SPST 5 res. A @ 250 VAC (5 res. A @ 30 VDC) output
(electromechanical relay) which can be set via configuration
parameter as alarm output/solenoid valve/resynchronization valve.
Electromechanical relay
Maximum switching power: 1,250 VA (150 W).
Mechanical life: > to 5,000,000 operations.
Electrical life: > to 100,000 operations.
Protection: none.
The device ensure a reinforced isolation among each terminal of
the digital output and the remaining parts of the device.
Bipolar stepper motor output:
4 wires bipolar stepper motor output.
Bipolar stepper motor output
Input voltage: 21 VDC ±10%.
Output voltage: 27... 36 VDC (18... 24 VDC if
supplied by the backup module).
Maximum output current: 1 A.
Driver type: chopper (constant current).
Protection: none.
Type of actions and additional features: 1C.
Communication ports: EPD4BX3 EPD4BC3 EPD4BF3 EPD4DF3

Related product manuals