C5 0 240 min 10
duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post blast chilling
storage; see also parameter C4
C9 0 240 min 30
duration of compressor switch-on during the cabinet probe
error (“Pr1” code) that occurs during post deep freezing
storage; see also parameter C4
Par. Min. Max. Unit Default Defrosting (5)
d0 0 99 h 8
defrosting interval (6)
0 = defrosting will never be activated at intervals
d1 0 3 - - - - 1
type of defrosting
0 = electrical (the compressor will be switched off during
defrosting, the defrosting output will be activated
and the evaporator fan will be switched off)
1 = hot gas (the compressor will be switched on during
defrosting, the defrosting output will be activated
and the evaporator fan will be switched off)
2 = air (the compressor will be switched off during
defrosting and the defrosting output will be
activated; the evaporator fan will be switched on,
independently from the conditions of the door, i.e.
independently from the door micro switch input
status)
3 = air with door open (the compressor will be switched
off during defrosting and the defrosting output will
be activated; the evaporator fan will be switched on,
on condition that the door is open, i.e. that is on
condition that the door micro switch is active and
that the parameter i0 is set at values different to 0)
d2 -99.0 99.0 °C/°F (1) 2.0
defrosting end temperature (evaporator temperature); see
also parameter d3
d3 0 99 min 30
if parameter P4 is set at 0, duration of defrosting
if parameter P4 is s et at 1, maximum duration of
defrosting; see also parameter d2
0 = defrosting will never be activated
d4 0 1 - - - - 0
defrosting on start-up of blast chilling and deep freezing
1 = yes