EVCO S.p.A. EVJ800 | Installer manual ver. 1.0 | Code 144J800E104
page 14 of 48
5.5 HACCP alarms
Access the SETTINGS menu with the key, select HACCP ALARMS and press to see the last 9 HACCP
alarms stored. If there are no HACCP alarms stored, the display will show the words “NO ALARM”.
The following HACCP alarms are listed:
- Blast chilling/blast freezing cycle duration
- Power failure
- Door open
- High temperature alarm
- Low temperature alarm
The time of their appearance will only be shown if an RTC is installed.
5.6 Restore data
Access the SETTINGS menu with the key, select RESTORE DATA and press . The RESTORE
PARAMETERS sub-menu can be accessed by first typing the password 149.
5.7 Real time clock
On the REAL-TIME CLOCK page, if the key is pressed, the 2 digits indicating the year start to flash. The value
can be set by using the keys, and then confirmed by pressing the key. Continue using this
procedure to complete the changes. Once the date and time have been set, you will be returned to the previous menu
after 50 seconds of inactivity or by pressing the key.