The display will show the count-down for the remaining time. At the end of the cycle the buzzer sounds for 1 second
and the device returns to the Home page.
6.10 Heating the needle probe
Heating of the needle probe is a cycle that is only available if the load managed by the K5 output is the needle probe
heater (u2 = 2).
The heating must be carried out with the door open but if the door is closed once the cycle has already started, it does
not affect its functioning.
Access the SPECIAL CYCLES menu from the key and select NEEDLE HEATING: at this point the start screen
will appear. The next time that is pressed the cycle will start, but it can be interrupted at any time by pressing
and holding the key down for 2 seconds.
The needle probe heating output is activated at maximum for the time set by parameter u8 or until the temperature
indicated by the needle probe has reached that set by parameter u7.
At the end of the heating, the buzzer sounds for one second and the device returns to the Home page.
6.11 Recipes
Recipes are preset ready-to-use programs that offer a series of cycles optimised by type of dish. When P3 is set to 0,
any recipes that call for a setpoint for the needle probe are not displayed.
The recipes can be modified before starting the cycle, but cannot be saved or over-written.
Access the SPECIAL CYCLES menu from the key and select RECIPES to see the list of predefined blast
chilling/blast freezing programs available. Using the keys select the desired recipe, change the setpoint
if necessary and start the cycle by pressing the key.