EVCO S.p.A. EVJ800 | Installer manual ver. 1.0 | Code 144J800E104
page 15 of 48
6 FUNCTIONS
6.1 Operating cycles
The device is capable of managing the following blast chilling and blast freezing cycles:
- temperature controlled blast chilling and conservation
- hard temperature controlled blast chilling and conservation
- time controlled blast chilling and conservation
- hard time controlled blast chilling and conservation
- temperature controlled blast freezing and conservation
- soft temperature controlled blast freezing and conservation
- time controlled blast freezing and conservation
- soft time controlled blast freezing and conservation
The blast chilling or blast freezing functions can be accessed quickly by pressing the keys and .
In addition to the blast chilling and blast freezing cycles, the controller is able to manage the following special cycles,
some of which are always available, while others can be enabled/disabled by parameters u1 (load managed by the K4
output) and u2 (load managed by the K5 output):
- pre-cooling
- manual defrosting
- fish sanitation (available if P3 = 1, i.e. if the needle probe is enabled)
- ice cream hardening
- thawing (available only if u1 is set to 2, i.e thawing heater)
- cabinet sterilisation (available only if u2 is set to 1, i.e UV lamp)
- needle probe heating (available only if u2 is set to 2, i.e. needle heater)
- recipes (programmes with predefined cycles)
The SPECIAL CYCLES menu is accessed by pressing the key.