TimeFactor User Guide System Menu Tree
45
clear the assignment before setting up a new assignment. In fact, the default settings use
this capability to provide both the normal Play functions and the Looper Play functions.
When done, Press the Middle Footswitch to go to top level System menu.
[MIDI] - MIDI Functions
After entering System mode, turn the Encoder to select [MIDI], then press the Encoder to
enter the MIDI functions settings mode.
Turn the Encoder to scroll through the MIDI functions including MIDI Program maps, MIDI
channel, MIDI Data Dumps, etc.
[RCV CH] Set the MIDI Receive Channel (OFF, OMNI, 1-16)
Press the Encoder to select. Turn Encoder to set the MIDI Receive Channel option. You can
select a MIDI Channel number, turn OFF MIDI receive or choose OMNI to receive on all MIDI
channels.
Press the Middle Footswitch once to back-up one level to MIDI menu.
Press the Middle Footswitch twice to go to top level System menu.
[XMT CH] Set the MIDI Transmit Channel (1, 2-16)
Press the Encoder to select. Turn Encoder to set the MIDI Transmit Channel.
Press the Middle Footswitch once to back-up one level to MIDI menu.
Press the Middle Footswitch twice to go to top level System menu.
[RCV CTL] - Receive Continuous Control Message
RCV CTL allows external MIDI Continuous Control messages to be used as assignable controls
for the Effects parameters and system control.
The idea is to first select the TimeFactor parameter or function that you want to externally
control (Mix for example) and then select either MIDI Bend or the MIDI CC with which you
want to control it.
Here’s how it works:
Press the Encoder to select RCV CTL. You will see two fields (split display) of the Billboard
display showing Parameter destination and Control source assignments. An arrow pointing to
the left (Parameter) is flashing (if its not, press the Left Footswitch to select this field) showing
this to be the selected field for editing.
To Setup Parameter Destination
Turn the Encoder knob to select an external control destination - the TimeFactor parameter or
function which will be controlled from an external source. The choices are:
BYP Bypass the unit
BK + Increment Bank number switch function
BK - Decrement Bank number switch function
TAP Tap tempo switch function
RPT Repeat function
P/B Toggle between Play and Bank Mode

Other manuals for Eventide TimeFactor