43
ABF 05-10-15
ENGLISH
The performance of the cycle continues in temperature modality any way.
To interrupt the buzzer pres key less
(decrease).
DEFROSTING
There are 3 modalities of defrosting cycle , precisely by air, electric and warmed gas, the activation of the cycles of de-
frosting can be automatic or manual (in detail in the following paragraphs).
Automatic Defrosting
During the maintenance, are performed if necessary cycles of automatic defrosting that are cyclically repeat for all
through the maintenance cycle. These defrosting cycles are activated only if the temperature of the probe evaporator is
inferior to the value of the parameter.
Automatic Defrosting At Started Cycle.
Is possible start a defrosting cycle in concomitance of a blast freezing cycle.
During the execution of the defrosting cycle it lights on
the defrosting led and the display DIS1 visualizes the label
“DEF.” The cycle finishes when the probe evaporator overcomes the value of the parameter or the timeout expires.
During the execution of a defrosting cycle the led DEFROSTING lights
on and the display DIS1 visualizes the
“DEF”. The blast/freezing cycle starts on only after the end of the defrosting cycle.
NOTE: if verified an evaporator probe alarm, the defrosting cycle starts any way, the end is determinate at the expire of
the timeout.
Manual Defrosting
The Defrosting key
allows the start on of a defrosting cycle only if there is’nt in performance a blast /freezing
cycle.
The defrosting cycle starts on, only in case the temperature of the evaporator is lower then the parameter.
The DEFROSTING led lights on
and the display DIS1 visualize the label “DEF”.
A manual defrosting cycle ends by the pressure of the key if the evaporator probe is highest then the value parameter
or by time out.
A cycle of manual defrosting can be performed even if a cycle of blast / freezing is selected.
Press the key START/STOP
to start the cycle of blast/freezing blocks an eventual defrosting manual cycle .
STERILIZATION (opt.)
To activate a cycle of sterilization cold room press the key Sterilization
: the relative led lights on and re-
mains turned on for all through the sterilization cycle.
The sterilization finishes by the pressure of the key Sterilization
or when the performance time expires.
The activation of the sterilization process is possible only if there aren’t other cycles in progress.
The open up of the door it stops the sterilization cycle.